sewer vent size??

stand up or sit down...to sink or not to sink...want or got gas...post your Q&A here..........

sewer vent size??

Postby jahyde » Fri Feb 05, 2016 11:56 am

So I know in general home construction 1.5" vents are mandated for a 3" drain.... But trying to keep vent sizes slim in my trailer, how many people have used 1 1/4 on the black tank?
jahyde
Teardrop Inspector
 
Posts: 6
Joined: Sun Aug 16, 2015 6:40 pm

Re: sewer vent size??

Postby Redneck Teepee » Fri Feb 05, 2016 3:25 pm

Your not getting it inspected so use what will fit in your space and call it good. 1-1/4" is plenty big :thumbsup:
Not sure what the I.D. of your wall or chase is but a 1-1/2" ABS/PVC vent pipe will measure 1-7/8" +/- O.D....1-1/4 will be 1-5/8" +/- O.D.
I fear the day that technology will surpass our human interaction, the world will have a generation of idiot's.
User avatar
Redneck Teepee
Silver Donating Member
 
Posts: 853
Images: 21
Joined: Fri Dec 27, 2013 5:00 pm
Location: Central Ca.

Re: sewer vent size??

Postby MtnDon » Fri Feb 05, 2016 4:11 pm

I used a 1" line from holding tank up to the roof vent where I adapted up to whatever size the RV roof vent needed. The tank fills and drains fine.
Our 6x12 deep vee nose cargo trailer camper conversion... viewtopic.php?f=42&t=58336

We have a small off grid cabin we built ourselves in the NM mountains; small PV solar system; 624 watts PV, Outback CC & inverter/charger ... http://countryplans.com/smf/index.php?topic=2335.0
User avatar
MtnDon
2000 Club
2000 Club
 
Posts: 2199
Images: 24
Joined: Sun Aug 19, 2012 10:57 pm
Location: New Mexico
Top

Re: sewer vent size??

Postby satch » Fri Feb 05, 2016 5:40 pm

Redneck Teepee wrote:Your not getting it inspected so use what will fit in your space and call it good. 1-1/4" is plenty big :thumbsup:
Not sure what the I.D. of your wall or chase is but a 1-1/2" ABS/PVC vent pipe will measure 1-7/8" +/- O.D....1-1/4 will be 1-5/8" +/- O.D.

Agreed, The vent pipe is meant to equalize the pressure of flow, so using a smaller vent just means draining might take a little longer. No big deal.
If it itches. scratch it
Rick
User avatar
satch
Donating Member
 
Posts: 1198
Images: 63
Joined: Thu Feb 07, 2008 9:46 pm
Location: the arm pit of Cali
Top

Re: sewer vent size??

Postby jahyde » Sat Feb 06, 2016 3:05 am

thanks... that makes me feel a bit better, I have worked a lot in home construction, and some associates even said "has to be 1.5", but I had a feeling it would breath just as well on 1".
jahyde
Teardrop Inspector
 
Posts: 6
Joined: Sun Aug 16, 2015 6:40 pm
Top

Re: sewer vent size??

Postby Dale M. » Sat Feb 06, 2016 11:18 am

Its just air and if there is very little resistance to flow, might get away with as little as 1/2 id tubing/pipe...

Dale
Lives his life vicariously through his own self.

Any statement made by me are strictly my own opinion.
You are free to ignore anything I say if you do not agree.

Image
User avatar
Dale M.
2000 Club
2000 Club
 
Posts: 2693
Images: 18
Joined: Thu Jun 09, 2005 8:50 pm
Location: Just a tiny bit west of Yosemite National Park
Top

Re: sewer vent size??

Postby Pleiades » Sat Feb 06, 2016 8:28 pm

Plumber here. . I have witnessed 3/8 inch copper line give enough air to flush a house toilet. So 1inch or probably be sufficient
Better to bring it and not need it...that whole thing.