Exactly, so if the drains have traps then why not one tank? Seems to me it is cheaper and simpler and easier, for my application to have one tank.
fromeo wrote:...
When plumbing your sink(s) don't forget an air admittance valve on each sink "stack." The siphoning action of water draining can actually draw the p-trap dry. Seen here in the top right corner, kind of hiding behind the sink bowl:
- Frank
StandUpGuy wrote:I was wondering about that. Why this valve instead of simply running a vent through the outside wall? Because of fumes coming in from the outside? One could manage a vent in the roof I suppose.
fromeo wrote:...
The tank needs an outside vent regardless - need some way for air to enter and exit the tank as the water level varies. I have permanent tanks, so venting through the roof was the obvious answer there.
Now, the air admittance valve is used because that pipe run from the sink to the tank is not vented to the outside. On my grey tank, I have 3 items draining into it - the galley sink, the bathroom sink, and the shower pan.
The shower pan is plumbed into the vent stack (it's only 6" from the shower drain to that pipe in my case) that runs up through the roof, so it does not get an air admittance valve.
The two sinks enter the tank seperately so they need the valve.
In theory you could run a vent through the roof (or even the wall) for each drain point. It's just not very practical. The valves allow you to "cheat" a little and run one vent, then the valves on any other pipe runs.
I'm not sure I'm explaining this very well with words. If a diagram would help, just let me know and I'll put something together explaining what I did. I also have a metric ton of pictures which may or may not help.
- Frank
StandUpGuy wrote:You can look at my build plans.
http://tnttt.com/viewtopic.php?t=43334
You will see my sink toilet and shower are inches from each other. I would just do as is in a house and have a main stack. In this case it does not have to be that large of a diameter. All drains will vent off of it and I will have no need for valves.