Yet another question about sharing conduit...

Anything electric, AC or DC

Yet another question about sharing conduit...

Postby Oregon Brew » Wed Apr 17, 2013 9:04 pm

I am planning on running AC, DC, and speaker wiring from the front of my cabin (where the headboard is), to the rear of the cabin (where the converter is). I'm putting it in Wiremold running along the sidewalls. Along the port side will be the AC and starboard will be the DC (see! I did learn something!)

Couple of questions - the AC I'm using is just standard household Romex in the white insulation. First question - should I run the wires without the white insulation or leave it on? I know there is probably no significant risk either way - Inside the Wiremold it probably won't overheat with it or wear significantly without it. I just thought I'd ask.

Second question - Can I run my speaker wiring in the same channel as my 12v or will that cause problems too? Please don't tell me I need to run a third set of channel!

Thanks in advance, oh Jedis of Electricity!
Oregon Brew
Teardrop Advisor
 
Posts: 56
Joined: Mon Oct 22, 2012 10:38 pm

Re: Yet another question about sharing conduit...

Postby Bogo » Wed Apr 17, 2013 9:28 pm

#1, Leave the exterior insulation on.

#2, You likely could, but there may be some cross talk. If there is you will need to separate them. If you could use shielded speaker wire it would help prevent cross talk.
User avatar
Bogo
500 Club
 
Posts: 658
Images: 39
Joined: Tue Oct 02, 2012 4:32 pm
Location: The land between two rivers.

Re: Yet another question about sharing conduit...

Postby Dale M. » Thu Apr 18, 2013 10:09 am

You can probably run speaker wires and 12 volt stuff in same channel.... You may get some electrical noise for some devices with electric motors into your audio, then maybe not....

Dale
Lives his life vicariously through his own self.

Any statement made by me are strictly my own opinion.
You are free to ignore anything I say if you do not agree.

Image
User avatar
Dale M.
2000 Club
2000 Club
 
Posts: 2693
Images: 18
Joined: Thu Jun 09, 2005 8:50 pm
Location: Just a tiny bit west of Yosemite National Park
Top

Re: Yet another question about sharing conduit...

Postby absolutsnwbrdr » Thu Apr 18, 2013 10:24 am

Oregon Brew wrote:Second question - Can I run my speaker wiring in the same channel as my 12v or will that cause problems too? Please don't tell me I need to run a third set of channel!


Every single car on the road has speaker wire run right along with all the 12VDC wiring.


ALL of my wires share the same piece of 1" conduit from front to back. 120VAC, 12VDC, some speaker wire, and a wired stereo remote control. Although for my 120VAC I simply cut up an outdoor-rated extension cord instead of using Romex. The conduit is packed tight. 2 years later and no issues.

Oh... and my 10GA wire for my 140W solar panel runs through there too.

Some people here will probably flame me for doing that, but I laugh in their faces. Its a camper. Its not a space shuttle. :D :lol:
Zach
Coming Soon...
Image Image
User avatar
absolutsnwbrdr
Donating Member
 
Posts: 2657
Images: 412
Joined: Mon Jan 25, 2010 6:10 pm
Location: Hanover, PA
Top

Re: Yet another question about sharing conduit...

Postby bobhenry » Thu Apr 18, 2013 10:38 am

DITTO HERE ! :thumbsup:
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top


Return to Electrical Secrets

Who is online