Insulation for ceiling?

Anything to do with mechanical, construction etc

Insulation for ceiling?

Postby IslandStorm62 » Sun Jun 09, 2013 4:24 pm

I am getting ready to put up the walls and run my spars from each wall; my issue is that the spars are 1" x 2", so if the y are installed wall to wall "vertically", that would give a 1.5" ceiling depth (space) between roof and headlining. At least this is how it looks on the Generic Benroy plans.

I guess I am wondering if everyone is using 1.5" thick insulation for the roof?

On the other hand, if the spars are installed wall to wall "horizontally", giving a 3/4" ceiling depth (space)would that not be more practical?

Of course this creates another dilemma...the last spars that support for the hatch needs to be "doubled and installed vertically for strength.

Can anyone give some clarity?

Thanks.
IslandStorm62
Teardrop Advisor
 
Posts: 90
Images: 13
Joined: Mon May 20, 2013 6:57 pm

Re: Insulation for ceiling?

Postby tamnalan » Sun Jun 09, 2013 4:58 pm

I installed them vertically. The 1.5" insulation won't hurt and your teardrop will be structurally stronger. Assuming you'll use some sort of ceiling vent - what is the vent's minimum thickness?

Oh, and my teardrop is tiny. Only 3' x 7', by 44" tall inside.

My $0.02
tamnalan
Teardrop Builder
 
Posts: 48
Joined: Fri Jan 06, 2012 9:12 am
Location: Oregon

Re: Insulation for ceiling?

Postby IslandStorm62 » Sun Jun 09, 2013 6:06 pm

Thanks, I did not think of the vent. I will be using the same standard 14 1/4 x 14 1/4 trailer vent.

I'm guessing that the vent is "a" if not the driving factor for the spars orientation. Looks like I'm going vertical to ensure I have consistency for the hatch and the vent.

Anyone else have additional info for me to consider.

Thanks again.
IslandStorm62
Teardrop Advisor
 
Posts: 90
Images: 13
Joined: Mon May 20, 2013 6:57 pm
Top

Re: Insulation for ceiling?

Postby mezmo » Sun Jun 09, 2013 7:28 pm

Installing the longest cross-section dimension of a piece of 1x in the
vertical position is always stronger as there is more material to resist
the tension and compression forces the span length imparts. The most
straightforward way to deal with insulation is to use the same thickness
as the spar's downward projection, then cover the combined spars and
insulation with the interior sheet covering. If that is a structural
material, like 1/8 or 1/4 inch plywood, and you glue that all together
you'd have a sandwich style torsion panel resulting from that. [Remember
everything glued tightly together reinforces each other and reacts as 'one',
or lends its strength to the other, when reacting to forces, sometimes quite
synergistically - so to say.]

If you wanted to put in thinner insulation between the spars, for the look
of it, say, just measure and cut the insulation to fit the needed dimensions
and cover that with your interior ceiling covering and trim for the resulting
edges. That'd be more time and trouble, and not as strong either, than
the first described method, in my view.
If you have a house - you have a hobby.
User avatar
mezmo
1000 Club
1000 Club
 
Posts: 1817
Images: 194
Joined: Fri Jan 01, 2010 4:11 am
Location: Columbia, SC
Top

Re: Insulation for ceiling?

Postby bobhenry » Mon Jun 10, 2013 7:21 am

As just said a 3/4 x 1 1/2 actual spar should be oriented with the 1 1/2 depth in the vertical. As to insulation sheet foam has always been my choice and no you don't have to buy 1 1/2 foam.
1/2 and 3/4 are most common and somewhat cheaper so 3 layers of 1/2 or 2 layers of 3/4 will also work well. I used butyl tape to help secure the foam to the spars on my 4 x 7 build.

Image

Image
Last edited by bobhenry on Mon Jun 10, 2013 7:42 am, edited 1 time in total.
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top

Re: Insulation for ceiling?

Postby les45 » Mon Jun 10, 2013 7:36 am

A word of caution about buying the 1/2" foam at the big box stores. I needed to fill the 1.5" thickness of my 1X2 spars so I bought the 1/2" foam at Home Depot with the idea of three layers to get the desired thickness. Turns out the foam was actually 9/16" so three layers ended up being too thick. I finally settled on using just two layers with an air gap. Measure the stuff in the store before buying to make sure it is truly the size you are looking for.
User avatar
les45
500 Club
 
Posts: 974
Images: 605
Joined: Sat Feb 25, 2012 8:57 am
Location: Aiken, South Carolina
Top

Re: Insulation for ceiling?

Postby planovet » Mon Jun 10, 2013 10:53 am

For my spars, I ripped 2x4s down to allow for just enough room for 2 layers of the sheet foam.

Image

After first layer:

Image

The second layer covered all the wires.
ImageMark (& Cindi)
Visit our website: Little Swiss Teardrop

I was wondering why the water balloon was getting bigger... and then it hit me.

ImageImageImageImage
User avatar
planovet
The Cat Man
 
Posts: 5583
Images: 3
Joined: Tue Nov 27, 2007 4:48 pm
Location: Plano, Texas
Top

Re: Insulation for ceiling?

Postby Forrest747 » Mon Jun 10, 2013 11:25 am

DO NOT GET THE WHITE FOAM. Make sure you get the foam that does not have little beads in it. I did the walls in blue insulation which was easy to work with but the white stuff did not like my cutting tool and had little beads of insulation everywhere and it stuck to every thing. For the roof i did two layers of 3/4 the lower one i would make spaces for the lights and wires and then a solid piece over. The doors also were insulated with the white stuff.
86191
87135
http://s1060.photobucket.com/user/forrest74769/media/Charley/IMG_9547small_zps6f442c73.jpg.html
http://s1060.photobucket.com/user/forrest74769/media/Charley/IMG_8701_zpsea29e11f.jpg.html
"All the success on the trail can not compensate for having square headlights"

"I've got a fever and the only prescription is more cowbell!"
http://www.tnttt.com/viewtopic.php?f=50&t=37701 Build Journal
User avatar
Forrest747
Cowbell Donating Member
 
Posts: 1327
Images: 447
Joined: Mon Apr 06, 2009 3:40 am
Location: West Valley Utah, Utah
Top

Re: Insulation for ceiling?

Postby working on it » Mon Jun 10, 2013 9:12 pm

Even though I never planned for it, I may end up needing some insulation on my ceiling, also. I painted the 3/4" plywood on both sides with two coats of aluminum reflective silo paint (outside over two coats of poly mix), thinking that that would be enough to shed the heat of the Sun. I read where the reflective ability of just the aluminum (silver) flakes in the paint were comparable to the foil-faced insulation (of course, minus the foam-fiberglass-or denim backing). But, the other day, while testing the battery charger inside the cabin, I was made aware of the heat build-up in the cabin, despite the A/C. I never thought of the fact that the roof/ceiling, though reflective, would still be heated by thermal conduction (from the Sun or inside heat or outside air temp), and without any insulation inside, would keep and transfer that to the cabin below. I should've known that...I've had trucks with no headliner that would cook your brains, until you added even the thinnest headliner as a radiant barrier, whether operating by thermal diffusion or just by creating an air space below the heated steel. So, since I'm sure to be over my trailers goal weight , another few pounds of insulation couldn't hurt! I am considering this http://www.homedepot.com/p/t/100656748?productId=100656748&storeId=10051&langId=-1&catalogId=10053&MERCH=REC%2d%5f%2dNavPLPHorizontal1%2d1%2d%5f%2dNA%2d%5f%2d100656748%2d%5f%2dN#.UbZ9iFko5kQ that could be easily retro-fitted onto my ceiling and sloping front wall. And, since I always intended to have a silver ceiling, the foil facing down would be just a little shinier. I was considering Dynamat, but can't justify that kind of $$$. $18 is more like it. One piece would be all I need. Think it'll help?
2013 HHRv "squareback/squaredrop", rugged, 4x8 TTT, 2225 lbs
  • *3500 lb Dexter EZ-Lube braked axle, 3000 lb.springs, active-progressive bumpstop suspension
  • *27 x 8.5-14LT AT tires (x 3) *Weight Distribution system for single-beam tongue
  • *100% LED's & GFCI outlets, 3x fans, AM/FM/CD/Aux. *A/C & heat, Optima AGM, inverter & charger(s)
  • *extended-run, on-board, 2500w generator *Coleman dual-fuel stove & lantern, Ikea grill, vintage skillet
  • *zinc/stainless front & side racks *98"L x 6" diameter rod & reel carrier tube on roof
173193172890148599
User avatar
working on it
2000 Club
2000 Club
 
Posts: 2189
Images: 457
Joined: Tue Oct 04, 2011 9:05 pm
Location: DFW Texas
Top

Re: Insulation for ceiling?

Postby aggie79 » Tue Jun 11, 2013 3:05 pm

I used 1x2s on edge insulated with 2 layers of 3/4" extruded polystyrene foam. The foam was a little over in thickness so I ran a few passes of the belt sander over it. I used spray foam to fill in around my wiring. In the last picture you'll see a tip that I picked up from someone on the forum. Write measurements to your wiring so when you're attaching the outer plywood you'll know where to not place fasteners.

Image

Image

Image
Tom (& Linda)
For build info on our former Silver Beatle teardrop:
Build Thread

93503
User avatar
aggie79
Super Duper Lifetime Member
 
Posts: 5405
Images: 686
Joined: Tue Aug 07, 2007 5:42 pm
Location: Watauga, Texas
Top


Return to Teardrop Construction Tips & Techniques