The only thing I'm converting is the plug pattern. (and adding a ground)
I have a 30 amp, 3 wire dryer circuit. I plan to replace the 3-prong receptacle with a 4-prong 50 amp receptacle, and to connect the existing ground wire that is already in the box. (10/3 Romex + ground) I will replace the dryer cord to match. (It will still be a 30 amp/240 volt circuit. I'm not changing the breaker.) This allows me to plug in a commonly used, '50 amp/240 volt to 30 amp' RV adapter and get what I need. It also upgrades my dryer circuit by adding the ground. (I'll need to make sure the ground wire is connected to the bus in the house panel.)

I understand that bonding the frame to the AC ground doesn't ground the system. The ground comes from a shore power connection. I don't plan to use a generator. I've grown to hate the sound after several hurricanes.