Here's a few pics of the Dickinson wood stove install.
I used the 22" single pipe coming up from the stove attached to pellet stove (double wall) elbow .
((Yes single wall can go into double wall but not vise versa))
The elbow goes through the door attached to a Tee with a cleanout, then to a 24" section of double wall.
That's 5+ feet of pipe.
It calls for 4 at the minimum.

I modified the top stove bracket for quick assembly/removal.

After mock-up and outside testing, I cut back the wood in the door another 1/2" and used some hi-temp tape
(Up to 400°) to wrap the edge then put the wall thimble back on. Also grabbed some exhaust wrap to add extra insurance going through the door but that didn't work out. PITA to assemble the two pieces and try to wrap it through the door.

Went back to autozoo and grabbed the starter shield.
Cut it down and sewed it up using fire resistant thread at work.
This installed much easier.


Sent from my SM-A115AP using Tapatalk