insulation

Anything to do with mechanical, construction etc

insulation

Postby timlsalem » Sun Feb 21, 2010 8:06 pm

I will be full timing it and just wondering if anyone knows if a 13 R value will be good for all weather conditions? :thinking:
KIA'S--MIA'S--POW'S--DAV'S--are what our freedom cost us
User avatar
timlsalem
Teardrop Master
 
Posts: 276
Images: 40
Joined: Sun Feb 14, 2010 11:36 am
Location: Centerville, Ohio

Postby Shadow Catcher » Sun Feb 21, 2010 9:03 pm

It is if you have enough heat or cool to make up for the loss. :)
User avatar
Shadow Catcher
Donating Member
 
Posts: 6008
Images: 234
Joined: Sat Apr 11, 2009 8:26 pm
Location: Metamora, OH

Postby timlsalem » Mon Feb 22, 2010 6:53 am

We're only talking about 140 cubic feet here so, space heater would work just fine then, right? :applause:
KIA'S--MIA'S--POW'S--DAV'S--are what our freedom cost us
User avatar
timlsalem
Teardrop Master
 
Posts: 276
Images: 40
Joined: Sun Feb 14, 2010 11:36 am
Location: Centerville, Ohio
Top

Postby len19070 » Mon Feb 22, 2010 7:09 am

"R"13 should be more than enough.

Big RV manufacturers don't even use that much. :oops:

Most won't even tell you what there "R" factor is using sayings like "exceeds industry standards" or "The highest in the industry" or just plain "Insulated".

Happy Trails

Len
:peace: :peace: :peace: :peace: :peace:
http://s26.photobucket.com/user/len1907 ... 20trailers

"If you do good things, good things will happen to you"..... Earl Hickey
User avatar
len19070
3000 Club
3000 Club
 
Posts: 3054
Images: 24
Joined: Tue Aug 17, 2004 7:44 pm
Location: S.E Pa. Morton
Top

Re: insulation

Postby bobhenry » Mon Feb 22, 2010 8:06 am

timlsalem wrote:I will be full timing it and just wondering if anyone knows if a 13 R value will be good for all weather conditions? :thinking:


How are you getting R 13 ?

Batts require a 3 1/2 wall cavity and foam requires a 2 - 2 1/2" wall cavity.

Compressing an R 13 batt in a skinny wall will NOT still give you R 13.

I installed 2 layers of 3/4 foam in "The Barn" for an honest R 8 and with a inexpensive 1500 heater I was well over 100 degrees (at the roof) and a comfortable 75 at the bed with 18 degree outside temp. This is heating just under 300 cubic feet.

Image
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top

Postby Steve_Cox » Mon Feb 22, 2010 8:33 am

I am also a bit curious how one would get R 13 inna teardrop wall, floor and ceiling. 8)
Steve
User avatar
Steve_Cox
4000 Club
4000 Club
 
Posts: 4903
Images: 196
Joined: Sun Apr 03, 2005 8:46 am
Location: Albuquerque New Mexico
Top

Postby bobhenry » Mon Feb 22, 2010 8:45 am

Steve_Cox wrote:I am also a bit curious how one would get R 13 inna teardrop wall, floor and ceiling. 8)


2x4 wall studs ???? :scratchthinking:

Guess I shouldn't have ripped mine down to save weight :cry:

Image
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top

Postby Classic Finn » Mon Feb 22, 2010 11:49 am

Just a quick question. :thinking: How does the regular type house insulation hold up in tears? I see Lil Guy and few other companies use this type of insulation. You,d think if it gets wet or damp by a leak..it would need to be totally repaired.. :thinking: :roll:

Here its called fiberglass wool insulation. Directly translated from Finnish to English.
Royal Teardrop Society Scandinavian Bureau Chief of Staff

Image
User avatar
Classic Finn
Midnight Sun Voyager
Midnight Sun Voyager
 
Posts: 17488
Images: 146
Joined: Fri Apr 29, 2005 4:29 am
Location: Country of Finland
Top

Postby Ageless » Mon Feb 22, 2010 12:50 pm

Fiberglass batts should not be used unless totally encased in plastic. Vibrations from travel break the fibers which become airborne or settle to the bottom. Having torn down several 1960 era trailers, insulation is a joke. They use f/g that is about 1/4" thick.
Strangers on this road we are on; we are not two, we are one - Raymond Douglas Davies
User avatar
Ageless
Platinum Donating Member
 
Posts: 1603
Images: 8
Joined: Tue Aug 04, 2009 8:34 am
Location: Pt. Orchard, WA
Top

R-13

Postby timlsalem » Thu Feb 25, 2010 8:14 am

I am taking 2x3's, which is actually a 1 1/2"x2 1/2 and ripping them to a true 2" and these will be my framing. Lowe's has foam insulation board that come's in 2"x4'x8' with an R-value of 6.5 per 1" thickness.
KIA'S--MIA'S--POW'S--DAV'S--are what our freedom cost us
User avatar
timlsalem
Teardrop Master
 
Posts: 276
Images: 40
Joined: Sun Feb 14, 2010 11:36 am
Location: Centerville, Ohio
Top

fiberglass

Postby timlsalem » Thu Feb 25, 2010 8:23 am

My first TD I used fiberglass and used plastic as a vapor seal. It worked great except when it got wet. Won't ever use fiberglass again. I do have a question about my doors. Both my TD's doors swelled when in damp weather. How do you rid yourself of this problem? I've tried wood sealers and everything with no remedy.
KIA'S--MIA'S--POW'S--DAV'S--are what our freedom cost us
User avatar
timlsalem
Teardrop Master
 
Posts: 276
Images: 40
Joined: Sun Feb 14, 2010 11:36 am
Location: Centerville, Ohio
Top

Postby claw73 » Thu Feb 25, 2010 9:50 pm

Since we're all talking about insulation, do people insulate the bottom of their teardrops? If so, how? Or do you just count the bed as the bottom insulation?

Thanks!
claw73
Teardrop Advisor
 
Posts: 64
Images: 28
Joined: Tue Feb 23, 2010 5:35 pm
Location: Bozeman MT
Top

Postby starleen2 » Thu Feb 25, 2010 10:13 pm

claw73 wrote:Since we're all talking about insulation, do people insulate the bottom of their teardrops? If so, how? Or do you just count the bed as the bottom insulation?

Thanks!


Some do - some don't - it's a matter of preference. IMO - a 4 Inch foam mattress is a pretty good insulator
User avatar
starleen2
5th Teardrop Club
 
Posts: 16272
Images: 224
Joined: Sat May 12, 2007 8:26 pm
Location: Pea Ridge ,AR
Top

Postby Conestoga » Thu Feb 25, 2010 11:33 pm

timlsalem, claw73,
We were in a hurry and bought a 4'x8' tear-like trailer to take on a winter vacation. Being tent campers with no trailer experience, in our minds what is between us and the cold ground is most important.... So we retrofitted the inner floor with 1" foam board, topped it with a carpet, and then the 3" foam mattress (a series of cushions) and summer sleeping bags. It worked great, including several nights at just above freezing. Preheating with a little ceramic heater on low for approx. 20 minutes was all it took to warm the cabin into those insulation layers before we crawled in to sleep. We will do the same thing or a variation of it if we eventually build our own. See the middle of this thread or my album for pix. The roof/curve is also insulated but not the side walls. However if building from scratch my preference would be to insulate on all sides, regardless of climate.
User avatar
Conestoga
Donating Member
 
Posts: 261
Images: 22
Joined: Wed Dec 30, 2009 12:01 pm
Location: Central PA
Top

Re: fiberglass

Postby Conestoga » Fri Feb 26, 2010 1:24 am

timlsalem wrote:I do have a question about my doors. Both my TD's doors swelled when in damp weather. How do you rid yourself of this problem? I've tried wood sealers and everything with no remedy.


growing up in PA, humidity & swinging temps, ah, metal exterior doors were the greatest new thing since.. ehh..hmm...

get new doors? anything not made of wood :R
User avatar
Conestoga
Donating Member
 
Posts: 261
Images: 22
Joined: Wed Dec 30, 2009 12:01 pm
Location: Central PA
Top

Next

Return to Teardrop Construction Tips & Techniques

Who is online

Users browsing this forum: No registered users and 4 guests