Will Vasaline inside a composit wall be ok?

Anything to do with mechanical, construction etc

Will Vasaline inside a composit wall be ok?

Postby dh » Mon May 17, 2010 1:34 am

I'm running some wires inside my walls before I glue on the final skin and want to put something on them to keep them from getting glued to the wall. Will Vasaline hurt anyting if used inside the wall?
Ignorant doesn't know any better, Stupid knows better but does it anyway.

My build page: http://www.tdbuildlog.blogspot.com/
User avatar
dh
Gold Donating Member
 
Posts: 1647
Joined: Fri Aug 14, 2009 7:08 pm
Location: North East Arkansas

Postby Miriam C. » Mon May 17, 2010 7:15 am

:thinking: Dunno. You can certainly use some clear tape. Just be sure you know where they are so you don't drill through them later........ :thumbsup:
“Forgiveness means giving up all hope for a better past.â€
User avatar
Miriam C.
our Aunti M
 
Posts: 19675
Images: 148
Joined: Wed Feb 15, 2006 3:14 pm
Location: Southwest MO

Postby bobhenry » Mon May 17, 2010 7:26 am

The insulation sheathing on most all coated elctrical wire is oil and solvent resistant. I would not hesitate to use it. Another idea would be cooking spray or cooking oil. When large commercial buildings are done in conduit they use a pulling lube to allow the long runs and large bundles of wires to slide easily thru the conduit. I am certain it is similar in composition.

If you want the real stuff any electrical supply houe will have one of these brands.......

http://www.toolup.com/ideal/cable-pulling/cable-pulling-lube/

One thought is petrolatum is oil based and will continue to wick for a long while possibly soaking thru the wood fiber and affecting any interior finishes you try to apply if it is able to travel that far. KY jelly is water base and will evaporate in a few days. It is water base and water soluable for easy cleanup ..... and using up the leftovers could be great fun :roll:
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top

Postby starleen2 » Mon May 17, 2010 7:57 am

bobhenry wrote: ..... and using up the leftovers could be great fun :roll:


:o :o
User avatar
starleen2
5th Teardrop Club
 
Posts: 16272
Images: 224
Joined: Sat May 12, 2007 8:26 pm
Location: Pea Ridge ,AR
Top

Postby Arne » Mon May 17, 2010 8:15 am

why do you care if it gets glued to the wall?

I would not use anything that might get absorbed into the wood and keep the finish from sticking... it might migrate through the panel to the other side, but am not sure about that one.
www.freewebs.com/aero-1
---
.
I hope I never get too old to play (Arne, Sept 11, 2010)
.
User avatar
Arne
Mr. Subject Line
 
Posts: 5383
Images: 96
Joined: Fri Aug 13, 2004 12:25 pm
Location: Middletown, CT
Top

Postby dh » Mon May 17, 2010 2:41 pm

The way they are running, if i leave a large tail out of the hole where they enter the celing, the wall will not be able to lay flat on the floor for gluing. I was going to coil up some extra in the larger switch opening and pull them out the top after wall is glued.
Ignorant doesn't know any better, Stupid knows better but does it anyway.

My build page: http://www.tdbuildlog.blogspot.com/
User avatar
dh
Gold Donating Member
 
Posts: 1647
Joined: Fri Aug 14, 2009 7:08 pm
Location: North East Arkansas
Top

Postby bobhenry » Tue May 18, 2010 8:03 am

dh wrote:The way they are running, if i leave a large tail out of the hole where they enter the celing, the wall will not be able to lay flat on the floor for gluing. I was going to coil up some extra in the larger switch opening and pull them out the top after wall is glued.


Just a thought .....

If you lay down new sheets of blue foam it will allow equal pressure on all areas and yet compress where there is a point load. When you pick up your wall there will be an imprint of the wires in the foam but the veneer side will have had the exact same pressure all over. It will also protect from small rocks and variations in the concrete. You can use the foam later in the roof so it will not be a waste.
Growing older but not up !
User avatar
bobhenry
Ten Grand Club
Ten Grand Club
 
Posts: 10368
Images: 2623
Joined: Fri Feb 09, 2007 7:49 am
Location: INDIANA, LINDEN
Top

Postby Shadow Catcher » Tue May 18, 2010 8:26 am

Oil/petroleum will attack rubber and some plastics. Silicone such as Armorall will not. You can also use dry lubes, heck I have even used dry antiperspirant
User avatar
Shadow Catcher
Donating Member
 
Posts: 6008
Images: 234
Joined: Sat Apr 11, 2009 8:26 pm
Location: Metamora, OH
Top

Postby dh » Tue May 18, 2010 9:50 pm

bobhenry wrote:
dh wrote:The way they are running, if i leave a large tail out of the hole where they enter the celing, the wall will not be able to lay flat on the floor for gluing. I was going to coil up some extra in the larger switch opening and pull them out the top after wall is glued.


Just a thought .....

If you lay down new sheets of blue foam it will allow equal pressure on all areas and yet compress where there is a point load. When you pick up your wall there will be an imprint of the wires in the foam but the veneer side will have had the exact same pressure all over. It will also protect from small rocks and variations in the concrete. You can use the foam later in the roof so it will not be a waste.


Hmm, I might have to think about that.
Ignorant doesn't know any better, Stupid knows better but does it anyway.

My build page: http://www.tdbuildlog.blogspot.com/
User avatar
dh
Gold Donating Member
 
Posts: 1647
Joined: Fri Aug 14, 2009 7:08 pm
Location: North East Arkansas
Top

Postby dh » Tue May 18, 2010 9:54 pm

Shadow Catcher wrote:Oil/petroleum will attack rubber and some plastics. Silicone such as Armorall will not. You can also use dry lubes, heck I have even used dry antiperspirant


Stick deoderant? Maybe it will keep the glue odors at bay :lol: :lol: :lol:

I might have to experiment with some dry lubes :thinking:
Ignorant doesn't know any better, Stupid knows better but does it anyway.

My build page: http://www.tdbuildlog.blogspot.com/
User avatar
dh
Gold Donating Member
 
Posts: 1647
Joined: Fri Aug 14, 2009 7:08 pm
Location: North East Arkansas
Top

Postby wannabefree » Tue May 18, 2010 9:56 pm

Why not use the stuff electricians use. It goes by various nicknames - slickum and gorilla snot is what I know it by. Get it at any big box in the electrical department. Comes in quart squeeze bottles and 5 gallon buckets. My guess is a quart will do :D
In anything at all, perfection is finally attained not when there is no longer anything to add, but when there is no longer anything to take away.
-- Antoine de Saint-Exupery
User avatar
wannabefree
The 300 Club
 
Posts: 380
Images: 82
Joined: Fri Jul 11, 2008 11:00 pm
Location: Phoenix
Top

Postby Shadow Catcher » Wed May 19, 2010 6:48 am

dh
This was the spray on antiperspirant, leaves a white powder and it will not attack rubber. Talcum powder will also work, as will penetrant developer. I was having a very difficult time telling where an oil leak was coming from and picked up a can of developer from a welding supply place, it is basically talc in a can and used with visible and fluorescent dye penetrant testing.
User avatar
Shadow Catcher
Donating Member
 
Posts: 6008
Images: 234
Joined: Sat Apr 11, 2009 8:26 pm
Location: Metamora, OH
Top

Postby dh » Wed May 19, 2010 7:26 pm

Shadow Catcher wrote:dh
This was the spray on antiperspirant, leaves a white powder and it will not attack rubber. Talcum powder will also work, as will penetrant developer. I was having a very difficult time telling where an oil leak was coming from and picked up a can of developer from a welding supply place, it is basically talc in a can and used with visible and fluorescent dye penetrant testing.


Dualy noted, I was starting to wonder about baby powder. Might spend more time this weekend experimenting on this than building a teardrop :lol:
Ignorant doesn't know any better, Stupid knows better but does it anyway.

My build page: http://www.tdbuildlog.blogspot.com/
User avatar
dh
Gold Donating Member
 
Posts: 1647
Joined: Fri Aug 14, 2009 7:08 pm
Location: North East Arkansas
Top

Postby Micro469 » Wed May 19, 2010 7:59 pm

wannabefree wrote:Why not use the stuff electricians use. It goes by various nicknames - slickum and gorilla snot is what I know it by. Get it at any big box in the electrical department. Comes in quart squeeze bottles and 5 gallon buckets. My guess is a quart will do :D


Have you ever tried to pull wire out of a conduit after electricians filled it with "gorilla snot"? They don't budge......... :thumbdown:
John
Image
User avatar
Micro469
Super Lifetime Member
 
Posts: 3185
Images: 382
Joined: Mon Nov 07, 2005 10:46 pm
Location: Brampton,Ontario,Canada
Top


Return to Teardrop Construction Tips & Techniques

Who is online

Users browsing this forum: Google [Bot] and 3 guests