Postby atcNick » Thu Sep 05, 2013 4:14 pm

I'm insulating my trailer with prodex and insulation board. Do you guys cover the "ribs" with anything? It's 100° outside and they're pretty warm to the touch on the inside of the trailer even with the AC running

Image
Image
-Nick
atcNick
Teardrop Advisor
 
Posts: 50
Joined: Sat Aug 17, 2013 11:16 am

Re: Insulation question

Postby OverTheTopCargoTrailer » Thu Sep 05, 2013 4:54 pm

If you want the best insulation check my build ,
You can cool 7 x 18 in 100 deg full sun only with 5,000 window AC
Same with the heating, it's just a matter of what is cost effective in your case.




http://overthetopcargotrailer.blogspot.com/
User avatar
OverTheTopCargoTrailer
1000 Club
1000 Club
 
Posts: 1628
Images: 0
Joined: Sun Jun 26, 2011 8:53 pm

Re: Insulation question

Postby jwhite » Thu Sep 05, 2013 5:18 pm

I used 2 layers of foam board and it was flush with the metal studs, I am sure that is enough but I sealed all the spaces with grey duct tape, it's cheap and just looked more finished.
I covered it back up with the plywood and covered that with carpet and bead board on the ceiling.
jwhite
The 300 Club
 
Posts: 479
Images: 46
Joined: Wed Mar 24, 2010 10:11 am
Location: South GA
Top

Re: Insulation question

Postby roadinspector » Thu Sep 05, 2013 9:25 pm

I put duct tape over my wall studs. It was supposedly good tape but about 25% of it dropped off as I was putting the plywood wall covering back up. I did not replace those pieces. My thinking on that is 1: screw it, I got other rabbits to kill that are more important, 2: I considered that it would help with air flow inside the walls hoping to help keep condensation from forming. I am not having any probs with temps with a 5050 btu unit cooling my 7x7x16. I can't hang meat in there but I am very comfortable when working in it.
Hope this helps. Good luck with your build.

Earnest
Dadgum it! I cut that board 5 times and it's still too short!
2001 quad-cab Dodge Cummins 3/4 ton camper special, 16x7x7 CT work in progress toyhauler, 01 HD Ultra Classic, 98 HD Heritage Softail, 88 HD 1200 Sportster. viewtopic.php?f=42&t=51510
User avatar
roadinspector
500 Club
 
Posts: 599
Images: 127
Joined: Wed Mar 24, 2010 10:33 pm
Location: Texas
Top

Re: Insulation question

Postby Treeview » Thu Sep 05, 2013 9:43 pm

Are your ribs Z channels or tubing?

If they're tubing you should consider using foam in a can insulation to fill the voids and break the thermal bridge.

The ceiling 'joists' in my ToyBox are rectangular aluminum tubing. I drilled holes in them so that I could get the nozzle to the right and left then squirted. After doing that I could touch the joists that were insulated but not the sheathing/aluminum roof. The hollows that I haven't foamed or encased with insulation are VERY hot compared to the ceiling joists or places that have insulation.

Tom
User avatar
Treeview
The 300 Club
 
Posts: 498
Images: 30
Joined: Sun Nov 27, 2011 9:22 am
Location: Land of 10,000 Lakes
Top

Re: Insulation question

Postby OverTheTopCargoTrailer » Thu Sep 05, 2013 10:15 pm

If you decide to go nuts with the foam,
Make sure it's non expanding foam, or your exterior will have bumps & lumps.

I did my door to fill the voids and it looked pregnant when I was done

Good luck
User avatar
OverTheTopCargoTrailer
1000 Club
1000 Club
 
Posts: 1628
Images: 0
Joined: Sun Jun 26, 2011 8:53 pm
Top

Re: Insulation question

Postby OverTheTopCargoTrailer » Thu Sep 05, 2013 10:22 pm

PS Earnest

Isn't 110 deg about normal weather for TEXAS ?? In the summer

I thought you don't need AC until at least 120 deg F at 10 am morning :D :D :D

With all my insulation my 7 x 6 x 18 has now become a 6 x 5 x 16 ,
Maybe that's why the AC works sooooo good :thumbsup: :thumbsup:

LOLROTF !!!
User avatar
OverTheTopCargoTrailer
1000 Club
1000 Club
 
Posts: 1628
Images: 0
Joined: Sun Jun 26, 2011 8:53 pm
Top

Re: Insulation question

Postby Treeview » Thu Sep 05, 2013 10:28 pm

OverTheTopCargoTrailer wrote:With all my insulation my 7 x 6 x 18 has now become a 6 x 5 x 16 ,


You're pulling a foamie now ;) :lol:

Tom
User avatar
Treeview
The 300 Club
 
Posts: 498
Images: 30
Joined: Sun Nov 27, 2011 9:22 am
Location: Land of 10,000 Lakes
Top

Re: Insulation question

Postby grantstew8 » Fri Sep 06, 2013 1:55 am

Hi
It is all about priority and budget. This is not a house you'll need to keep cool 24x7x365 so you may feel that it's not worth the extra cost/time. We had this a lot with steel and sips building.

If you fill a tube with foam it does nothing. The inside is insulated but the heat/cold is transferred around the insulation by the steel, there is no physical break. One problem we have here (uk is cold not hot) is condensation on the inside. Warm moist air comes in contact with cold steel and you get a condensation drip.

In you case insulating from the outside is not possible now so a thin layer of hyper performing (read expensive) insulation over the steel tubes would do the trick.

There are some paints that are good insulators used in the ship/submarine world. Again these are eye watering prices

If all else fails, a thin layer of foam is better than nothing.....
User avatar
grantstew8
The 300 Club
 
Posts: 448
Images: 77
Joined: Tue May 28, 2013 5:26 pm
Location: Dunfermline, Scotland
Top

Re: Insulation question

Postby len19070 » Fri Sep 06, 2013 6:13 am

grantstew8 wrote:If you fill a tube with foam it does nothing. The inside is insulated but the heat/cold is transferred around the insulation by the steel, there is no physical break.


I'm with Grant on this. Metal, as in your metal studs is a conductor and not an insulator.

If its Hot/Cold on the outside, its Hot/Cold on the inside.

As it looks now the only insulating break you have is the Plywood.

One thing that may help is if you finish off the inside walls with some kind of Foam Backed Rug over the plywood.

But also, very important cover the metal with something that won't let Moisture transfer through to the Plywood.

Happy Trails

Len
Last edited by len19070 on Sat Sep 07, 2013 7:01 am, edited 3 times in total.
:peace: :peace: :peace: :peace: :peace:
http://s26.photobucket.com/user/len1907 ... 20trailers

"If you do good things, good things will happen to you"..... Earl Hickey
User avatar
len19070
3000 Club
3000 Club
 
Posts: 3054
Images: 24
Joined: Tue Aug 17, 2004 7:44 pm
Location: S.E Pa. Morton
Top

Re: Insulation question

Postby OverTheTopCargoTrailer » Fri Sep 06, 2013 9:41 am

Here is how you build a foamie trailer :D :D :D



a wood wall pic.JPG
a wood wall pic.JPG (135.07 KiB) Viewed 5032 times


photo 1-2.JPG
photo 1-2.JPG (141.46 KiB) Viewed 5032 times



double foam wall.JPG
double foam wall.JPG (99.53 KiB) Viewed 5032 times



JUST DONT ask what it costs :cry: :cry:
User avatar
OverTheTopCargoTrailer
1000 Club
1000 Club
 
Posts: 1628
Images: 0
Joined: Sun Jun 26, 2011 8:53 pm
Top

Re: Insulation question

Postby Willuz » Fri Sep 06, 2013 11:53 am

I used extra wide Gorilla tape to cover the studs and hold the insulation in. It sticks great even in extreme heat and it's thick enough to provide some insulation between the plywood and the metal stud. The most important place to seal is the top of the insulation, otherwise the hot air just rises up and out the top into your trailer.
Willuz
Teardrop Inspector
 
Posts: 20
Images: 8
Joined: Thu Aug 30, 2012 4:49 pm
Top

Re: Insulation question

Postby jwhite » Fri Sep 06, 2013 12:00 pm

The Gorilla tape is Great Tape it cost more but worth it, it's thicker and really sticks to anything.
I had never used it until I built my trailer, now I keep a roll around for everything.
jwhite
The 300 Club
 
Posts: 479
Images: 46
Joined: Wed Mar 24, 2010 10:11 am
Location: South GA
Top

Re: Insulation question

Postby grantstew8 » Fri Sep 06, 2013 12:33 pm

Willuz wrote:I used extra wide Gorilla tape to cover the studs and hold the insulation in. It sticks great even in extreme heat and it's thick enough to provide some insulation between the plywood and the metal stud. The most important place to seal is the top of the insulation, otherwise the hot air just rises up and out the top into your trailer.


Thermal bypass is a major issue where air is able to flow from one side of the insulation to the other and in essence makes the insulation almost useless. What Willuz says is important.

If you are building a house, I can't stress how important it is to avoid thermal bypass. The position of the insulation within the wall/roof and seal of insulation is vital or it's a waste of time/money and will cost a fortune to heat/cool. $>
It's been a soap box of mine for a while. :SG

I could bore y'all senseless but the essence of it is, make sure the insulation is in tight and sealed with tape.
User avatar
grantstew8
The 300 Club
 
Posts: 448
Images: 77
Joined: Tue May 28, 2013 5:26 pm
Location: Dunfermline, Scotland
Top

Re: Insulation question

Postby OverTheTopCargoTrailer » Fri Sep 06, 2013 1:08 pm

Grant my Bro -

We are beating a dead horse over here, they all just slap up 1" el cheapo $100 worth of foam between the metal studs with some duct tape
Some even think they get R35 with the 1/8" silver plastic bubble wrap :lol:
and then they fire up the old 13,000 Btu ac & 40,000 Btu heater buddy and swear how good it works :? :? :?
most can't even see the condensation pouring from the walls :lol: , its on the back side of the plywood.

Psssssssst , for heavens sake don't wait for them to do the floor , side door or the large rear cargo door
those never loose any heat ....

sooner or latter, with some dumb luck we will find a convert,
but when he finds out what that DOW Blue board costs he will get scared off
:frightened:
The cost for 3" dow Blue board on 7 x 18 is around $1,000