Rainier70 wrote:I would suggest that you also coat the roof with a solar reflective paint like Henry's Solar Flex. It makes a huge difference on summer temperatures.
texaskreek06 wrote:Mike S, Thanks for the info. I do not plan on having any DC, don't think I will have a need for it. Curious if you would explain yourself with needing so many roof vents? I have a 15,000 btu a/c w/ heat pump planned, a top of the line one from what I can tell. Also, Not sure if I understand room vents, but wouldn't they just hinder the cooling/heating process? As far as power, I had just planned on running 110 into a breaker and having my 50 amp cord hooked into my breaker out to my plug on the side of the building. Would you recommend running the wiring through pvc conduit or some type of conduit? Also, how much room did you have between your plywood walls and the exterior metal? Thanks
texaskreek06 wrote:Mike, I plan on using romex, which has its own insulation, however I wasn't sure if that would be enough. I plan on insulating everything and running the wire between, but maybe I'll run some pvc conduit. I definitly will add some vents. I have been seeing the Fan-Tastic around a lot lately, maybe I will put one of them in the bathroom and another on the other side of the CT from the A/C. That was one of the things I wasn't sure about. Thanks for the tips.... now If I could get a definite on plumbing I would feel about better.
Mike S wrote:texaskreek06 wrote:Mike, I plan on using romex, which has its own insulation, however I wasn't sure if that would be enough. I plan on insulating everything and running the wire between, but maybe I'll run some pvc conduit. I definitly will add some vents. I have been seeing the Fan-Tastic around a lot lately, maybe I will put one of them in the bathroom and another on the other side of the CT from the A/C. That was one of the things I wasn't sure about. Thanks for the tips.... now If I could get a definite on plumbing I would feel about better.
It sounds like your plumbing will be pretty easy. I used red and blue, 1/2 inch PEX piping, brass fittings, and steal crimps. That's essentially residential grade plumbing. In 12 months the system has been trouble free. I have a 35 gallon freshwater tank and 12 volt water pump as well as the option for a shore connection. In your case, it sounds like you'll just have a shore water. If you're using any RV fixtures (like an RV sink or showerhead) you'll need to control your water pressure with a pressure regulator because RV stuff is designed for 50 PSI or less. If you're using residential fixtures it's probably not an issue.
texaskreek06 wrote:Mike S wrote:texaskreek06 wrote:Mike, I plan on using romex, which has its own insulation, however I wasn't sure if that would be enough. I plan on insulating everything and running the wire between, but maybe I'll run some pvc conduit. I definitly will add some vents. I have been seeing the Fan-Tastic around a lot lately, maybe I will put one of them in the bathroom and another on the other side of the CT from the A/C. That was one of the things I wasn't sure about. Thanks for the tips.... now If I could get a definite on plumbing I would feel about better.
It sounds like your plumbing will be pretty easy. I used red and blue, 1/2 inch PEX piping, brass fittings, and steal crimps. That's essentially residential grade plumbing. In 12 months the system has been trouble free. I have a 35 gallon freshwater tank and 12 volt water pump as well as the option for a shore connection. In your case, it sounds like you'll just have a shore water. If you're using any RV fixtures (like an RV sink or showerhead) you'll need to control your water pressure with a pressure regulator because RV stuff is designed for 50 PSI or less. If you're using residential fixtures it's probably not an issue.
Mike, I would like to not have to flush tanks, and my sewer is in the ground, in fact I will run a vertical pipe up just so I can access it and hook into it from the trailer. If I run just pipes to the sewer, do you see any reason why I might have issues? I think as long as I have gravity and a slope on my side it should function smoothly. I was originally going to install tanks for possible future use, but a member pointed out that once solids hit the tank they lose their flowing powers. So I was thinking of just using pipe, and then if I every needed tanks I could add them or use portable tanks. What are your thoughts?
I had planned on using all residential plumbing fixtures(low flow) and appliances.
I noticed is seams like Fan-tastic Vents and pretty much everything I have come across from on 12v DC power, any idea where I mind find something similar that will run on AC power?
Your insight has been more than appreciated!