Electrical umbilical

Anything electric, AC or DC

Electrical umbilical

Postby CarlS » Fri Jan 01, 2010 12:36 pm

I have a typical situation of wires going into the galley lid to feed speakers, turn signals, etc(nine total). I realized early on that I would need a plug to the inside of the interior cabinet to disconnect so as to remove the galley lid during construction. Now that I have this put together, I'm noticing a too stiff to deal with umbilical cord. Would it be reasonable to drop wire gauge for this umbilical section, ie; a computer cable or something like that? I could have a plug/inspection plate on the ceiling of the galley for my second plug or junction.
Carl
User avatar
CarlS
Teardrop Inspector
 
Posts: 18
Images: 29
Joined: Mon Nov 09, 2009 4:52 pm
Location: Snohomish,WA

Postby Miriam C. » Fri Jan 01, 2010 3:24 pm

I used a ordinary trailer wire on the lights and a 4 prong adapter to disconnect.....Only have the lights on it. I would put everything on another circuit.

There are lots of disconnects and a trip to the auto parts store will find them. :thumbsup: btw what size wire are you using? 14 thhn should be good enough. Actually a lot of trailers are wired with 16. No reason you can't use speaker wire for the speakers........just fuse accordingly. 8)
“Forgiveness means giving up all hope for a better past.â€
User avatar
Miriam C.
our Aunti M
 
Posts: 19675
Images: 148
Joined: Wed Feb 15, 2006 3:14 pm
Location: Southwest MO

Postby CarlS » Fri Jan 01, 2010 10:10 pm

I'm using 14 gauge wire. I think the answer will be to use a short section(the exposed area) of some small gauge flat multi wire. I was at a party today and spotted an unfinished hole in the wall that was slated for an intercom. There was my answer...some flat, small gauge 4 or 5 wire feed. I wanted to pull it out and cut it!
User avatar
CarlS
Teardrop Inspector
 
Posts: 18
Images: 29
Joined: Mon Nov 09, 2009 4:52 pm
Location: Snohomish,WA
Top

Postby Miriam C. » Fri Jan 01, 2010 10:32 pm

CarlS wrote:I'm using 14 gauge wire. I think the answer will be to use a short section(the exposed area) of some small gauge flat multi wire. I was at a party today and spotted an unfinished hole in the wall that was slated for an intercom. There was my answer...some flat, small gauge 4 or 5 wire feed. I wanted to pull it out and cut it!


yep mine is a 4 flat! ;) the break away part is up to you
“Forgiveness means giving up all hope for a better past.â€
User avatar
Miriam C.
our Aunti M
 
Posts: 19675
Images: 148
Joined: Wed Feb 15, 2006 3:14 pm
Location: Southwest MO
Top

Postby Shadow Catcher » Sat Jan 02, 2010 8:38 am

Easiest solution would be to use Anderson Power Poles which can be configured in what ever manner (I am using them for solar).
http://www.newhamstore.com/powerpole-he ... at_52.html
User avatar
Shadow Catcher
Donating Member
 
Posts: 6008
Images: 234
Joined: Sat Apr 11, 2009 8:26 pm
Location: Metamora, OH
Top

Postby planovet » Sat Jan 02, 2010 9:28 am

Miriam C. wrote:I used a ordinary trailer wire on the lights and a 4 prong adapter to disconnect.


That's what I did and it works well. It's exposed but I don't mind, makes it easy to get to if I ever have to disconnect them to remove the hatch. One wire goes to my tail lights on the hatch and the other is split into 2 circuits...one for the hatch light and one for the red LEDs in the hatch.

Image

Image
ImageMark (& Cindi)
Visit our website: Little Swiss Teardrop

I was wondering why the water balloon was getting bigger... and then it hit me.

ImageImageImageImage
User avatar
planovet
The Cat Man
 
Posts: 5583
Images: 3
Joined: Tue Nov 27, 2007 4:48 pm
Location: Plano, Texas
Top